dc.description.abstract | Hip and knee articulations are the main joints in human body and they have the duty of sustaining
heavy loads. This task is normally well performed by a healthy joint but, in some cases, the
occurrence of diseases can affect the functionality of the joint: when ambulation is limited, surgery
is required.
Even if the orthoprosthesis is one of the most effective and successful surgical procedure in
the modern medicine, around the 10% of the implanted devices will fail and so require a second
surgery. The revision operation is a difficult procedure which needs a long scheduling prior to
surgery.
Currently, hip and knee joint prostheses are analysed and subjected to simulation tests
before receiving the required approval for clinical use. These tests are performed with the aim of
establish the behaviour of the prosthesis, assess the wear rate of the components and the surface
finishing. However, wear tests on a simulator are long and expensive due to the large number of
cycles at low frequency that must be executed. The idea was to move toward an in-silico wear
assessment.
In order to define which are the most influencing parameters on the tribology of the implants
it was investigated the Metal Transfer. It is a migration phenomenon of metal particles found on
femoral heads and on acetabular cups of retrieved ceramic hip prostheses, which implies an
important alteration of the bearing surface. The presence of transferred metal on ceramic heads
changes the surface properties and thus affects lubrication, friction and wear. They were studied 35
ceramics femoral heads of different materials, including zirconia, Biolox® Delta, Biolox® and
Biolox® Forte. Differences in surface characteristic appear, as an evidence of the phenomenon,
between the affected and unaffected areas... [edited by Author] | it_IT |
dc.language.iso | en | it_IT |
dc.publisher | Universita degli studi di Salerno | it_IT |
dc.subject | Implant | it_IT |
dc.subject | Biomechanics | it_IT |
dc.subject | Tribology | it_IT |
dc.title | Tribological characterization and in-silico wear assessment of lower limb joint prosthesis | it_IT |
dc.type | Doctoral Thesis | it_IT |
dc.subject.miur | ING-IND/13 MECCANICA APPLICATA ALLE MACCHINE | it_IT |
dc.contributor.coordinatore | Reverchon, Ernesto | it_IT |
dc.description.ciclo | XVI n.s. (XXX ciclo) | it_IT |
dc.contributor.tutor | Ruggiero, Alessandro | it_IT |
dc.identifier.Dipartimento | Ingegneria Industriale | it_IT |
dc.relation.info | PON 2000-2006 “Ricerca Scientifica, Sviluppo Tecnologico, Alta Formazione”. Regioni dell’Obiettivo 1 – Misura III.4 “Formazione superiore ed universitaria” | it_IT |
dc.contributor.referee | Hloch, Sergej | it_IT |
dc.contributor.referee | Bruschi, Stefania | it_IT |